Liebherr SKBes 4210-24 Installation Manual Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 14
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
u
Lift the stopper
Fig. 8 (33)
out of the door bearing bush and
transfer it.
u
Dismantle the door handle
Fig. 8 (32)
, stoppers
Fig. 8 (33)
and pressure plates*
Fig. 8 (34)
and transfer to the opposite
side.
u
When fitting the pressure plates on the opposite side, make
sure they snap properly into place.*
4.3.6 Fitting the door
u
Place the door from above onto the lower bearing pin
Fig. 6 (22)
.
u
Close the door.
u
Insert the upper turn hinge
Fig. 4 (12)
in the door on the new
hinge side.
u
Screw the upper turn hinge
Fig. 4 (12)
firmly into place (with
4 Nm)(2x Torx® 25)
Fig. 4 (13)
. Possibly make preliminary
holes with a bradawl or use a cordless screwdriver.
u
Snap the cover
Fig. 4 (10)
and cover
Fig. 4 (11)
into place at
the opposite side.
4.3.7 Aligning the door
u
Align the door to the appliance housing by way of the two
oblong holes in the bottom turn hinge
Fig. 6 (25)
. To do so,
unscrew the middle screw.
WARNING
Risk of injury due to the door dropping out!
If the bearing parts are not screwed into place firmly enough,
the door may drop out. This may lead to severe injuries. What
is more, the door may not close and therefore the appliance
may fail to cool properly.
u
Screw the turn hinges firmly into place with 4 Nm.
u
Check all of the screws and retighten if necessary.
4.4 Insertion into a row of kitchen units
Fig. 9
(1) Stack cabinet (3) Kitchen cabinet
(2) Appliance (4) Wall
When inserting the appliance into a row of kitchen units (max.
depth 580 mm), the appliance can be installed directly next to
the kitchen unit
Fig. 9 (3)
. The appliance door projects relative
to the front of the kitchen unit by 34 mm at the side and by
50 mm in the middle of the appliance. It can be opened and
closed perfectly as a result.
Important for the ventilation:
-
At the back of the stack cabinet there has to be a ventilation
duct of at least 50 mm depth throughout the width of the
stack cabinet.
-
The ventilation space under the ceiling has to be at least
300 cm
2
.
-
The larger the ventilation space, the more energy-saving the
appliance is in operation.
If the appliance is installed with the hinges next to a wall
Fig. 9 (4)
, the distance between appliance and wall has to be at
least 40 mm. This corresponds to the projection of the handle
when the door is open.
4.5 Disposing of packaging
WARNING
Danger of suffocation due to packing material and plastic film!
u
Do not allow children to play with packing material.
The packaging is made of recyclable materials:
-
corrugated board/cardboard
-
expanded polystyrene parts
-
polythene bags and sheets
-
polypropylene straps
-
nailed wooden frame with polyethylene panel*
u
Take the packaging material to an official collecting point.
4.6 Connecting the appliance
NOTICE
Risk of damage to the electronic control system!
u
Do not use stand-alone inverters (conversion of d.c. to a.c./
three-phase) or energy saving plugs.
WARNING
Fire and overheating hazard!
u
Do not use extension cables or multiple socket outlets.
The type of current (alternating current) and voltage at the
installation site have to conform with the data on the type plate
(see Appliance at a glance).
Connect the appliance only with a properly installed
socket outlet with earthing contact. The socket outlet
must be fused with 10 A or higher.
It must be easily accessible so that the appliance can
be quickly disconnected from the supply in an emer-
gency. It must be outside the area of the rear of the
appliance.
u
Check the electrical connection.
u
Plug in the power plug.
4.7 Switching on the appliance
u
Press On/Off button
Fig. 3 (3)
.
w
The temperature display indicates the current temperature.
w
The interior light is on when the door is open.
Putting into operation