A delight in freshness
HC 1001 / HC 1050
6
INSTALLATION
Figure 5
Kitchen Cabinet Construction
This is a fully integrated refrigerator-freezer which
means that it is fully enclosed by a kitchen cabinet.
This type of cabinet must be carefully constructed
using the proper dimensions and it must provide
proper ventilation to ensure proper appliance opera-
tion.
Kitchen Cabinet Airflow
1. The following ventilation dimensions must be
observed:
There must be a ventilation space at
least 31 in.
2
(200 cm
2
) at the airflow inlet
(Fig. 4, 1) and at the airflow outlet (Fig. 4, 2).
There must be a clear ventilation space
(without any obstructions) of at least
1-1/2 in. (38 mm) at the back of the kitchen
cabinet (Figure 5).
The top ventilation space can be either
directly over the appliance (Fig. 4, 2) or next
to the ceiling over a cabinet (Fig. 4, 3), or
through a vent installed in a soffit (Fig. 4, 4).
2
1
4
3
Figure 4
Page view 10