HCB 1560/1561HC 15507084 327-00Installation InstructionsFor Fully Integrated NoFrost Combined Refrigerator-Freezers
10IcemakerSafety Instructions and Warnings • Donotinstallthewaterconnectionwhilethecom-bined refrigerator-freezer is connected to an electri-
11IcemakerFigure 19Figure 17Figure 209. Open the shut-off valve for the water supply and check the entire water system for leaks.Connection to the Wat
Fastening the Appliance in the Recess - Figure 22Fasten the appliance in the recess through the pre-mounted securing plates at left and right on the a
Adjusting the Refrigerator Door - Figure 23IMPORTANTUnder normal conditions, the factory adjustment of the refrigerator door should not be changed. On
6. Insert the locking pins to block the supports (Figure 29). Mounting the Ventilation Grille1. Pull out the bottom freezer drawer.2. Remove the blue
7. Install the ventilation grille (Figure 30). The grille has bolts on the inside (see detail in Figure 30 a). These bolts must be inserted into th
Mounting the Attachment Brackets onto the Door Panels - Figure 34Mark a line with a distance of 41" and 4-1/4" from the bottom of the refrig
2. Open the refrigerator door and hang the panel on the top adjusting bolts (Figure 36).3. Screw on the hex nuts to the adjusting bolts and fin-ger ti
Figure 4211. Click cover 1 into place. Insert the cover strip provided 2 between refrig-erator door and panel (Figure 42).10. Loosen the three screw
Mounting the Freezer Drawer Panels - Figure 431. Pull out the upper freezer drawer and screw on the panel with three screws on the left and right side
2ImportantContent PageUnit Dimensions ... 4Door Swing Clearance ...
For Service in the U.S.LiebherrServiceCenterToll Free: 1-866-LIEBHERor1-866-543-2437Email: [email protected]Solutions,I
3SafetyDisposal of Old Appliance DANGER!Risk of child entrapment. Child entrapment and suffocation are not problems of the past. Junked or abandone
Unit Dimensions - Figure 1, Figure 2Unit Venting - Figure 4HCB appliances do not require any ventilation openings in the cabinet. The required air flo
Cabinet Opening Dimensions - Figure 5IMPORTANTDo not install the shut-off valve behind the appliance. Cabinet HeightInset cabinet Depth DFrameless/fac
Panel Dimensions - Inset Installation Style - Figure 6Figure 6The panels should be at least 5/8 inch (16 mm) thick to allow the connecting rails to be
Panel Dimensions - Frameless Installation Style - Figure 7Figure 7Cabinet opening C Refrigerator door panel D80" (2032 mm) 45-3/4" (1162 mm)
WARNING! • Theantitippingbracketmustbemountedtoprevent the appliance from tipping when the fully stocked door is opened.• Besurethatth
MountingtheAntiTippingDeviceinCabinetsdeeper than 24" - Figures 12 - 13A proper function of the anti tipping bracket is warranted within a
Comments to this Manuals