Defrosting
The appliance defrosts automatically. The water that forms on the
rearwalldrainsintoareservoiratthebackoftheapplianceand
evaporates automatically through the compressor heat.
Safety lock
Thelockintheappliancedoorisequippedwithasafetymecha-
nism.
Locking the appliance
• Insert the key as shown by ar-
row 1.
• Turnthekey90°.
Tounlocktheappliance,thesame
procedure must be repeated in the
same order.
Setting the display indication for the defrost
phase
The following indications can be set for the defrost phase.
• Symbol
+alternatingdisplayof and the current tem-
perature in the interior of the appliance.
• Symbol
+temperaturebeforethestartofthedefrostphase
(factory setting).
• Symbol
+ .
Change the display during the defrost phase
Press for5seconds.Display=
Display=
Use buttons and to select the desired setting.
=alternating display of and the current temperature in
the interior of the appliance.
=temperature before the start of the defrost phase.
=displayof only.
Display=
Press for 5 seconds.
Theelectroniccontrolsystemwillswitchbacktonormaloperat-
ing mode.
Interior light MKUv 1613
Theinteriorlightisttedontheinsideatthetop.
The interior light can be switched
onandousingthe
button.
The light intensity of the LED
light corresponds to laser
class 1/1M.
Important
The light cover may only be
removed by customer service
sta.
If the cover is removed, do not look directly at the light
through optical lenses from close distance.
This can damage your eyes.