Alarm messages
1. LED flashes
If
appears in the display, the appliance has a fault.
Consultyournearestcustomerservicepoint.
2. LED
flashes and appears in the display
The power failure alarm battery is supplying too low a voltage
or is defective.
Consultyournearestcustomerservicepoint.
3. LED
flashes, the display reads HI or LO
The interior is too warm (HI) or too cold (LO).
The audible warning signal sounds.
4. HACCP flashes - the current interior temperature,
and
are displayed alternately
There has been a power cut of some length or the interior was
too warm or too cold during a certain period of time.
Up to three alarm events can be stored and called up.
Alarm test
Thistestchecksthefunctionoftheinternalandanyexternal
connected alarm device.
The appliance does not stop its refrigerating function during
this test.
Activating the test
Press
+ for 5 seconds.
• Thedisplaywillchangetoatemperaturevalueof0.2°Cbelow
the set upper alarm limit.
• Thetemperaturevaluewillnowriseby0.1°Cevery2seconds.
• When the upper alarm limit is reached,
will appear in the
display. An external alarm unit connected to the floating alarm
output will now be activated.
• Thetemperaturevaluewillcontinuetoriseupto0.2°Cabove
the upper alarm limit.
• Thesameprocesswilltakeplaceautomaticallyforthelower
alarm limit.
will appear in the display.
TheLED
will be lit during the test.
Theelectroniccontrolsystemwillautomaticallyswitchbackto
normal operating mode.
Cancelling the test prematurely
Press
for 5 seconds.
Audible warning signal settings
The audible warning signal will be muted for the current alarm
after the button
has been pressed.
Complete the following stepsifyouwantthe audible warning
signal to reactivate automatically.
Press
for5seconds.Display=
Display=
Display=
Display=
Display=
Display=
Display=
Display=
Display=
Automatic reactivation of the audible warning signal is now active.
The time before the audible warning signal sounds again must be set.
Display=
Display= Time in minutes after which the audible
warning signal will sound again after the
button
has been pressed. Setting
range=1-120minutes.
Use buttons
and to select the desired setting.
Display=
Press for 5 seconds.
Theelectroniccontrolsystemwillswitchbacktonormaloperat-
ing mode.